Temperature and Relative Humidity Data Logger – HTL-804

Temperature and Relative Humidity Data Logger – HTL-804

Product Description :

HTL-804 – 8 Channel T + RH Data logger with 2 common High / Low Alarm relay outputs + 16 independent relay drivers + Real time clock + Built in data storage + RS-485 serial interface or RS-232 for serial Dot-matrix printer.


HTL-804-U1 – Uses Rotronic make HYGROCLIP-XD sensors.


HTL-804-U2 – Uses Libratherm make HTS-440 sensors.


HTL-804-U3 – Uses Libratherm make HTS-220 sensors.


HTL-804-U4 – Uses any type of T+RH Transmitters giving 4-20mA signals.

Libratherm offers Microcontroller based 8 channel T + RH Data Logger Model HTLOG-804 which is designed for continuous, simultaneous, and very accurate monitoring and logging of temperature and Relative Humidity values at a maximum of 4 different locations. The logged data are stored in the internal memory in real-time and date. The logged data can also be monitored in the online mode on the PC screen and can also be downloaded to the PC in the offline mode. The facility is also available through the additional serial port to directly print the logged or stored data with real-time/date at the programmable PRINT INTERVAL on EPSON or equivalent Serial Dot Matrix printer.


The Model HTL-804 accepts input from standard T + Rh sensors or transmitters giving voltage or current signals. Users can specify the required type of sensor or transmitter based on what suits the application. If the data logging to be carried out on the small chambers or cold storages then only sensors are preferred. But if the sensing to be carried out across the long length and breadth of the warehouse, greenhouse, etc requiring long cables, then T + RH transmitters are preferred.


Other hardware features include 2 nos. of common for all channels high or low relay outputs, 16 nos. of transistor drivers – available to the user on 20 pin FRC connector and cable. FRC compatible 8 channel relay cards are also available. The respective front panel dual-color LEDs show the status of each channel – whether it is High (Red) or Low (green) when compared to their respective set values.


Standard features include programmable display SCAN time, channel SKIP, and HOLD facility with a manual increment of the channel number using a front panel membrane keyboard.

Key Features:
Applications:
Monitor and Log/Store at various locations T + Rh values in the cold storage, warehouses, stability chambers, walk-in chambers, HVAC systems like Humidifiers or Dehumidifiers, green houses etc.
Data storage with reference to storage interval:
Data Storage IntervalNo. of Channels Total Storage Duration
1 min85 days
5 min 828 days
10 min 856 days
15 min 884 days
30 min 8168 days
60 min8336 days
ParameterDescription
No. of channels8 nos. (4 Temperature + 4 %Rh)
Input type U1 0-1VDC proportional to Temperature and RH from Rotronic Hygroclip-XD
Input type U2Pt-100 + 0-3.3VDC proportional to Temperature and RH from HTS-440
Input type U3Pt-100 + 0-3.3VDC proportional to Temperature and RH from HTS-220
Input type U44-20mA proportional to Temperature and RH values - scalable
RangeFor Temperature -40 to 60 oC (U1) or -20 to 80oC (U2) OR 0 to 60oC (U3) For RH 0 to 100%.
AccuracyBetter than ± 0.3?C for temperature using class A Pt-100 element
Better than +/-1% (U1), Better than +/-3% RH (U2 and U3)
Display5 digit each 0.5" 7-segment Red /Green LED to indicate Temp and RH values,
Alarm values and Real Time Clock and 2 digit 0.3” 7-segment Red LED to display channel no.
Scan Rate1 to 99 sec (programmable through front panel keyboard)
Data Storage Interval1 to 99 minutes (user programmable).
Data Storage8000 records. (512KB).
Print Interval1 to 99 minutes (User programmable)
Skip/Hold FacilityAvailable through key board in configuration mode
High / Low AlarmCommon or individual Settable using key pad
Common Relay output2 nos. potential free change over contacts
(1 each for high and low output but common for all the channels)
Alarms Outputs (Optional)8 x 2 open collector outputs to drive external relay cards.
8 nos. for Temperature and 8 nos. for RH.
LED Indication8 x dual colour LEDs in the front indicating status of each alarm output.
Serial InterfaceRS-485 over MODBUS RTU protocol in the slave mode for PC interface or RS-232 serial port for dot matrix printer interface
(any one is available at a time)
Supply90V - 260VAC VAC ± 10% (10VA), 50/60Hz or 24VDC/AC @ 200mA
EnclosurePlastic enclosure with polycarbonate front graphic.
Size of DATALOG-80496 x 96 x 160 mm.
Size of the Relay Card RLY-8190 L x 120 W x 75 D mm (35 mm DIN rail mount)
CodeInputRange
A1Rotronic Hygroclip XD T+Rh sensor with 2 meter long cable-40 to 60°C / 0 to 100%Rh
A2Libratherm HTS-220 T + RH sensor with 2 meter long cable0 to 60°C / 0 to 100%Rh
A3Libratherm HTS-400 T + RH sensor with 2 meter long cable-20 to 80°C / 0 to 100%Rh
A4Hygrotx-3000 Transmitter using Hygroclip-XD sensor 2 x 4-20mA with 2 meter long cable-40 to 60°C / 0 to 100%Rh
A5Libratherm HTX-220 Transmitter 2 x 4-20mA with 2 meter long cable0 to 60°C / 0 to 100%Rh
A6Libratherm HTX-440 Transmitter 2 x 4-20Ma with 2 meter long cable0 to 60°C / 0 to 100%Rh
Sr. No.ModelDescriptionPart No.
Ordering Information for Model DATALOG-804-U1: Input from Hygroclip-XD Sensors
1.1HTL -804-U1Input: Type U1 (from Hygroclip XD sensor)
Output: 2 Common Relays
Serial Interface : RS-232 for Printer Interface
3005-1
1.2HTL -804-U1Input: Type U1 (from Hygroclip XD sensor)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-232 for Printer Interface
3005-2
1.3HTL -804-U1 Input: Type U1 (from Hygroclip XD sensor)
Output: 2 Common Relays
Serial Interface : RS-485 for Computer Interface
3005-3
1.4HTL -804-U1 Input: Type U1 (from Hygroclip XD sensor)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-485 for Computer Interface
3005-4
Ordering Information for Model DATALOG-804-U2: Input from HTS-440 Sensors
2.1HTL -804-U2 Input: Type U2 (from HTS-440)
Output: 2 Common Relays
Serial Interface : RS-232 for Printer Interface
3006-1
2.2 HTL -804-U2Input: Type U2 (from HTS-440)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-232 for Printer Interface
3006-2
2.3HTL -804-U2Input: Type U2 (from HTS-440)
Output: 2 Common Relays
Serial Interface : RS-485 for Computer Interface
3006-3
2.4HTL -804-U2Input: Type U2 (from HTS-440)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-485 for Computer Interface
3006-4
Ordering Information for Model DATALOG-804-U3: Input from HTS-220 Sensors
3.1 HTL -804-U3Input: Type U3 (from HTS-220)
Output: 2 Common Relays
Serial Interface : RS-232 for Printer Interface
3007-1
3.2HTL -804-U3Input: Type U3 (from HTS-220)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-232 for Printer Interface
3007-2
3.3HTL -804-U3Input: Type U3 (from HTS-220)
Output: 2 Common Relays
Serial Interface : RS-485 for Computer Interface
3007-3
3.4HTL -804-U3Input: Type U3 (from HTS-220)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-485 for Computer Interface
3007-4
Ordering Information for Model DATALOG-804-U3: Input from T+RH Transmitters
4.1 HTL -804-U4 Input: Type U4 (from T + RH Transmitters)
Output: 2 Common Relays
Serial Interface : RS-232 for Printer Interface
3008-1
4.2HTL -804-U4 Input: Type U4 (from T + RH Transmitters)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-232 for Printer Interface
3008-2
4.3HTL -804-U4 Input: Type U4 (from T + RH Transmitters)
Output: 2 Common Relays
Serial Interface : RS-485 for Computer Interface
3008-3
4.4HTL -804-U4Input: Type U4 (from T + RH Transmitters)
Output: 2 Common Relays
Relay Drivers: 16 transistor output to drive external 16 channel relay cards
Serial Interface : RS-485 for Computer Interface
3008-4
5.1MSI-RLY-8 8 channel relay card – compatible with DATALOG-804 3384-1

Product Category