Temperature and Humidity Transmitter with Display – HTX-3000


Temperature and Humidity Transmitter with Display – HTX-3000
Product Description :
HTX-3000 – Temperature and Humidity Transmitter with Display, 4-20mA/RS-485 Modbus/Ethernet Interface.
Libratherm offers micro-controller-based Temperature and Humidity Transmitter with Display – HTX-3000, 4-20mA output, RS-485 or Ethernet interface as per the user’s requirement. This Hygro Thermo Transmitter with digital indicator finds its application in Green House, Cold Storage Rooms, Server Rooms, Sterilizers, Pharmaceutical Clean Room and Food Product storage or manufacturing plants and all such similar areas where the measurement of T + Rh is important and critical and is required to be strictly monitored at the desired levels.
Applications:
- Microcontroller based design.
- Elegant appearance, easy to operate and compact in size.
- Highly accurate and sturdy in operation.
- Dual display for simultaneous indication of T and RH.
- Offers both Analog and Digital Serial Interface.
| Parameter | Description |
|---|---|
| Sensor | Hygroclip-XD or HTS-440 (common sensor for both T and RH) |
| Temperature Range | -40.0 to 60.0oC (Using Hygroclip XD Sensor) 0.0 to 60.0 oC (Using HTS-440 sensor) |
| Temperature Accuracy | Better than +/- 0.3 ?C |
| %RH Range | 0.0 to 100.0 %RH (Using Hygroclip XD Sensor) 10.0 to 100.0%RH (Using HTS-440 sensor) |
| RH Accuracy | Better than +/-1 %RH @ 25.0 ?C (using Hygroclip-XD sensor) Better than +/-3 %RH @ 25.0 ?C (using HTS-440 sensor) |
| Display for T and %RH | 4 digit each 0.3 Red / Green seven segment LED display |
| Power Requirement (*) | 24VDC @ 150mA (+/-10%) . |
| Output 1 for Temperature | 4-20mA proportional to 0 to 100.0 %RH (12 bit resolution) |
| Output 2 for %RH | 4-20mA proportional to 0 to 100.0 %RH (12 bit resolution) |
| Load Resistance | RLmax. = 400 Ohms @ 24VDC. |
| Serial Output (Optional) | Isolated 2 wire RS485 MODBUS RTU Slave protocol |
| Ethernet Port (Optional) | Ethernet port on RJ-45 jack with TCP/IP protocol. |
| Key board | Membrane key board is provided for programming the MODBUS address and for Range Calibration. |
| Enclosure (Size) | ABS plastic (120 x 80 x 55) mm. |
| Sensor Hygroclip XD | 14 x 140 mm with screw-on type plug and socket 14 x 170 mm + 2meter long cable |
| Sensor HTS-440 | 60 x 35 x 15 mm + 2 meter long cable |
| 24VDC Adapter (Optional) | 24VDC adapter working on 90-250VAC can be supplied along with HTX-3000. |
| Mounting / Cable Entry | Wall mounting using suitable clamps. Cable entry glands either at the left side or right side or at the rear side as per the requirement. |
| Sr. No | Product Description | Part No. |
|---|---|---|
| 1 | With Integrated Hygroclip XD Sensor and 2 x 4-20mA output | 3212-1 |
| 2 | With Integrated HTS-440 Sensor and 2 x 4-20mA output | 3212-2 |
| 3 | With 2 meter Hygroclip XD Sensor cable and 2 x 4-20mA output | 3213-1 |
| 4 | With 2 meter HTS-440 Sensor cable and 2 x 4-20mA output | 3213-2 |
| 5 | With Integrated Hygroclip XD Sensor and RS 485 Serial interface | 3214-1 |
| 6 | With Integrated HTS-440 Sensor and RS 485 Serial interface | 3214-2 |
| 7 | With 2 meter Hygroclip XD Sensor cable & RS 485 Serial interface | 3215-1 |
| 8 | With 2 meter HTS-440 Sensor cable & RS 485 Serial interface | 3215-2 |
| 9 | With Integrated Hygroclip XD sensor and EHTERNET Port RJ45 | 3216-1 |
| 10 | With Integrated HTS-440 sensor and EHTERNET Port RJ45 | 3216-2 |
| 11 | With 2 meter Hygroclip XD Sensor cable and ETHERNET Port | 3217-1 |
| 12 | With 2 meter HTS-440 Sensor cable and ETHERNET Port | 3217-2 |
Product Category
Digital Indicators
- Temperature Indicators
- Large Display Temperature Indicators
- Portable Thermometers
Temperature Controllers
- Ramp/Soak Temperature Controllers
- Multi Zone Ramp/Soak Controllers
- PWHT/SR Controllers
- PID Temperature Controllers
- On-Off Temperature Controllers
Data Loggers & Scanners
- Temperature Data Loggers
- Temperature Scanners
Temperature & Humidity Instruments
- Temperature and Humidity Sensors
- Temperature and Humidity Transmitters
- Temperature and Humidity Indicators
- Temperature and Humidity Controllers
- Clean Room Monitoring Systems
Thyristor Triggering Cards
- Thyristor Triggering Cards
- Zero Cross Over Triggering Cards
- Capacitor Bank Switch Cards (RTPFC)
Thyristor Power Controllers
Phase Angle Controllers
- Single Phase Thyristor Power Controllers
- Two Phase Thyristor Power Controllers
- Three Phase Thyristor Power Controllers
Zero Cross Over Switches
- Single Phase Thyristor Power Switches
- Three Phase Thyristor Power Switches
- Three Phase SSR
DC Rectifiers
- Single Phase Thyristor DC Rectifier
- Two Phase Thyristor DC Rectifier
- Three Phase Thyristor DC Rectifier
- Capacitor Bank Switches (RTPFC)
Signal Isolators & Conditioners
Signal Isolator DC to DC Signal
- Signal Isolator DC to DC – AC Operated
- Signal Isolator DC to DC – 24 VDC Operated
Signal Isolator AC to DC Signal
- Signal Isolator AC to DC – AC Operated
- Signal Isolator AC to DC – 24 VDC Operated
Signal Isolator Temperature to DC Signal
- Signal Isolator Temp to DC – AC Operated
- Signal Isolator Temp to DC – 24 VDC Operated
- Signal Isolator Frequency to DC Signal
- Signal Isolator with Display
- Load Cell Signal Conditioners
Transmitters
- Temperature Transmitters
- Process Transmitters
Motor Controllers
- DC Motor Controllers
- Motor Soft Starters
- Molten Metal Pyrometers
- IoT Modules
- Instrumentation Control Panels
- Product Accessories